Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 15.522
Filtrar
2.
Echocardiography ; 41(4): e15818, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38654654

RESUMEN

The assessment of LVDD is routinely included in echocardiographic evaluation because it correlates with cardiac disease progression and its prognostic value. Classic parameters used for assessing LV diastolic function correlate well with invasive measurements which remains the gold standard. Nevertheless, no one echocardiographic parameter alone can completely evaluate LVDD. LV diastolic function evaluation in atrial fibrillation is still challenging, since the E/A ratio, one of the most used parameters in echocardiographic evaluation, cannot be feasible. This is not a good reason to give up measurement. In this review, we analyze the different methods for estimating LV diastolic function in atrial fibrillation, including measurement not dependent on atrial systole and some novel methods that are promising, but not ever available during clinical practice highlighting that this assessment is mandatory for a complete clinical evaluation of the patients.


Asunto(s)
Fibrilación Atrial , Ecocardiografía , Disfunción Ventricular Izquierda , Humanos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología , Ecocardiografía/métodos , Diástole , Reproducibilidad de los Resultados
3.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38652090

RESUMEN

AIMS: Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) using very high-power short-duration (vHPSD) radiofrequency (RF) ablation proved to be safe and effective. However, vHPSD applications result in shallower lesions that might not be always transmural. Multidetector computed tomography-derived left atrial wall thickness (LAWT) maps could enable a thickness-guided switching from vHPSD to the standard-power ablation mode. The aim of this randomized trial was to compare the safety, the efficacy, and the efficiency of a LAWT-guided vHPSD PVI approach with those of the CLOSE protocol for PAF ablation (NCT04298177). METHODS AND RESULTS: Consecutive patients referred for first-time PAF ablation were randomized on a 1:1 basis. In the QDOT-by-LAWT arm, for LAWT ≤2.5 mm, vHPSD ablation was performed; for points with LAWT > 2.5 mm, standard-power RF ablation titrating ablation index (AI) according to the local LAWT was performed. In the CLOSE arm, LAWT information was not available to the operator; ablation was performed according to the CLOSE study settings: AI ≥400 at the posterior wall and ≥550 at the anterior wall. A total of 162 patients were included. In the QDOT-by-LAWT group, a significant reduction in procedure time (40 vs. 70 min; P < 0.001) and RF time (6.6 vs. 25.7 min; P < 0.001) was observed. No difference was observed between the groups regarding complication rate (P = 0.99) and first-pass isolation (P = 0.99). At 12-month follow-up, no significant differences occurred in atrial arrhythmia-free survival between groups (P = 0.88). CONCLUSION: LAWT-guided PVI combining vHPSD and standard-power ablation is not inferior to the CLOSE protocol in terms of 1-year atrial arrhythmia-free survival and demonstrated a reduction in procedural and RF times.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Atrios Cardíacos , Tomografía Computarizada Multidetector , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Venas Pulmonares/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Femenino , Masculino , Ablación por Catéter/métodos , Persona de Mediana Edad , Anciano , Atrios Cardíacos/cirugía , Atrios Cardíacos/diagnóstico por imagen , Factores de Tiempo , Resultado del Tratamiento , Recurrencia , Frecuencia Cardíaca , Potenciales de Acción
8.
J Cardiovasc Electrophysiol ; 35(5): 886-894, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38433316

RESUMEN

INTRODUCTION: Through systematic scientific rigor, the CLOSE guided workflow was developed and has been shown to improve pulmonary vein isolation durability. However, this technique was developed at a time when using power-controlled ablation catheters with conventional power ranges was the norm. There has been increased adoption of a high-power and very high-power short-duration ablation practice propelled by the availability of the temperature-controlled radiofrequency QDOT MICRO catheter. METHODS: There are fundamental differences in biophysics between very high-powered temperature guided ablation and conventional ablation strategy that may impact patient outcomes. The catheter's design and ablation modes offer flexibility in technique while accommodating the individual operator's clinical discretion and preference to deliver a durable, transmural, and contiguous lesion set. RESULTS: Here, we provide recommendations for 3 different workflows using the QDOT MICRO catheter in a step-by-step manner for pulmonary vein isolation based on our cumulative experience as early adopters of the technology and the data available in the scientific literature. CONCLUSIONS: With standardization, temperature-controlled ablation with the QDOT MICRO catheter provides operators the flexibility of implementing different ablation strategies to ensure durable contiguous pulmonary vein isolation depending on patient characteristics.


Asunto(s)
Fibrilación Atrial , Catéteres Cardíacos , Ablación por Catéter , Diseño de Equipo , Venas Pulmonares , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Humanos , Ablación por Catéter/instrumentación , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Factores de Tiempo , Resultado del Tratamiento , Frecuencia Cardíaca , Potenciales de Acción , Flujo de Trabajo , Temperatura
9.
J Cardiovasc Electrophysiol ; 35(5): 1007-1016, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38468346

RESUMEN

INTRODUCTION: Cather ablation (CA) is a well-recognized treatment alternative for atrial fibrillation (AF) patients despite more than 20% ablation-treated patients suffering from AF recurrence. The underlying mechanism of AF recurrence postablation is probably associated with high cardiac parasympathetic activity, which can be assessed with deceleration capacity (DC) of heart rate. Given that the relationship between DC and AF recurrence is still controversial, this systematic review and meta-analysis was performed to investigate the characteristics of DC in patients with and without AF recurrence, evaluating the prognostic value of DC in AF patients after CA. METHODS: A literature search was systematically performed in the Embase, PubMed, Web of Science, China National Knowledge Infrastructure (CNKI), and Wanfang databases until October 01, 2023. The observational studies reporting either the pre- and postablation DC in both recurrence and non-recurrence groups or the ratios based on DC for predicting AF recurrence were mainly included. Weighted mean differences (WMD) or odds ratios (OR) based on DC would be calculated with a random-effect model, if heterogeneity estimated with the I2 index and Q statistic was significant (I2 > 50% or p < .05); otherwise, a fixed-effect model would be utilized. RESULTS: A total of eight observational studies involving 914 AF patients treated with radiofrequency or cryoballoon ablation were included in this study. Ablation-treated patients with AF recurrence had the higher DC postablation in relation to those without recurrence (WMD, 1.00; 95% confidence interval [CI], 0.33-1.67; p < .01), which was present up to 3 months of follow-up (WMD, 1.54; 95% CI, 1.11-1.96; p < .01), whereas there was no statistical significance in DC before ablation between recurrence and non-recurrence groups (WMD, 0.34; 95% CI, -0.12 to 0.79; p = .15). The high DC postablation was a risk factor for AF recurrence in ablation-treated patients (OR, 2.17; 95% CI, 1.44-3.25; p < .01). CONCLUSION: The high DC postablation was associated with the risk of AF recurrence, suggesting that DC may act as a prognostic indicator in AF patients treated with CA.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Desaceleración , Frecuencia Cardíaca , Valor Predictivo de las Pruebas , Recurrencia , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Humanos , Ablación por Catéter/efectos adversos , Factores de Riesgo , Resultado del Tratamiento , Medición de Riesgo , Masculino , Femenino , Persona de Mediana Edad , Potenciales de Acción , Anciano , Factores de Tiempo , Adulto
10.
J Cardiovasc Electrophysiol ; 35(5): 1046-1049, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38468182

RESUMEN

INTRODUCTION: Left atrial appendage (LAA) closure (LAAC) is considered a viable alternative to anticoagulation therapy for stroke prevention in nonvalvular atrial fibrillation, we report a case with a less common shunt resulting from a device-related coronary artery-appendage fistula (CAAF) following LAAC. METHODS AND RESULTS: A 67-year-old male with a history of LAAC was referred to our emergency room with recurrent chest pain and palpitations and was diagnosed with ischemic angina pectoris. Subsequent coronary angiography (CAG) revealed 70% in-stent restenosis and an abnormal shunt of contrast originating from the left circumflex artery (LCA) to the LAA tip which did not exist before. The restenosis was successfully dilated using a drug-coated balloon, the procedure was safely completed without pericardial effusion. The patient had been implanted with a LAmbre occluder (Lifetech Scientific Corp.) in the previous LAAC procedure. This occluder had a lobe-disk design, and the distal umbrella was not fully opened after release, particularly in the lower portion. This could make the hooks embedded on the umbrella contact the LAA wall more tightly, possibly resulting in microperforation and coincidental impingement of the LCA. The epicardial adipose and hyperplastic tissue then chronically wrapped the perforated site, prevented blood outflow into the epicardium, and ultimately formed a CAAF. CONCLUSION: CAAF is a rare complication after LAAC but may be underestimated, especially for lobe-disk designed occluders. Therefore, CAG is perhaps necessary to detect this complication.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/fisiopatología , Masculino , Anciano , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Vasos Coronarios/diagnóstico por imagen , Dispositivo Oclusor Septal/efectos adversos , Fístula Vascular/diagnóstico por imagen , Fístula Vascular/etiología , Diseño de Prótesis , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , 60589
11.
J Cardiovasc Electrophysiol ; 35(5): 975-983, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38482937

RESUMEN

INTRODUCTION: Lesion size index (LSI) was introduced with the use of Tacticath™ and as a surrogate of lesion quality. The metric used to achieve the predetermined values involves combined information of contact force (CF), power and radiofrequency time. Rapid atrial pacing (RAP) and high-frequency low-tidal volume ventilation (HFLTV) independently or in combination improve catheter stability and CF and quality of lesions. Data of the impact of body weight adjusted HFLTV ventilation strategy associated with RAP in the lesion metrics still lacking. The study aimed to compare the results of high-power short-duration (HPSD) atrial fibrillation ablation using simultaneous weight adjusted HFLTV and RAP and standard ventilation (SV) protocol. METHODS: Prospective, nonrandomized study with 136 patients undergoing de novo ablation divided into two groups; 70 in RAP (100 ppm) + HFLTV with 4 mL/kg of tidal volume and 25 breaths/min (group A) and 66 patients with SV in intrinsic sinus rhythm (group B). Ablation using 50 W, CF of 5-10 g/10-20 g and 40 mL/minute flow rate on the posterior and anterior left atrial wall, respectively. RESULTS: No procedure-related complications. Group A: Mean LSI points 70 ± 16.5, mean total lower LSI 3.4 ± 0.5, mean total higher LSI 8.2 ± 0.4 and mean total LSI 5.6 ± 0.6. Anterior and posterior wall mean total LSI was 6.0 ± 0.4 and 4.2 ± 0.3, respectively. Mean local impedance drop (LID) points were 118.8 ± 28.4, mean LID index (%) 12.9 ± 1.5, and mean LID < 12% points 55.9 ± 23.8. Anterior and posterior wall mean total LID index were 13.6 ± 2.0 and 11.9 ± 1.7, respectively. Recurrence in 11 (15.7%) patients. Group B: Mean LSI points 56 ± 2.7, mean total lower LSI 2.9 ± 0.7, mean total higher LSI 6.9 ± 0.9, and mean total LSI 4.8 ± 0.8. Anterior and posterior wall mean total LSI was 5.1 ± 0.3 and 3.5 ± 0.5, respectively. Mean LID points were 111.4 ± 21.5, mean LID index (%) 11.4 ± 1.2, and mean LID < 12% points 54.9 ± 25.2. Anterior and posterior wall mean total LID index were 11.8 ± 1.9 and 10.3 ± 1.7, respectively. Recurrence in 14 (21.2%) patients. Mean follow up was 15.2 ± 4.4 months. CONCLUSION: Weight adjusted HFLTV ventilation with RAP HPSD ablation produced lower recurrence rate and better LSI and LID parameters in comparison to SV and intrinsic sinus rhythm.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Volumen de Ventilación Pulmonar , Humanos , Femenino , Proyectos Piloto , Masculino , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Estudios Prospectivos , Persona de Mediana Edad , Anciano , Ablación por Catéter/efectos adversos , Resultado del Tratamiento , Factores de Tiempo , Frecuencia Cardíaca , Estimulación Cardíaca Artificial , Peso Corporal
12.
J Cardiovasc Electrophysiol ; 35(5): 984-993, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38486082

RESUMEN

INTRODUCTION: Little is known about very early atrial fibrillation (AF) ablation after first AF detection. METHODS: We evaluated patients with AF ablation <4 months from newly diagnosed paroxysmal AF (NEWPaAF) and newly diagnosed persistent AF (NEWPeAF). We compared the two patient populations and compared ablation outcomes to those undergoing later ablation. RESULTS: Ablation was done <4 months from AF diagnosis in 353 patients (135 = paroxysmal, 218 = persistent). Early ablation outcome was best for NEWPaAF versus NEWPeAF for initial (p = 0.030) but not final (p = 0.102) ablation. Despite recent AF diagnosis in both groups, they were clinically quite different. NEWPaAF patients were younger (64.3 ± 13.0 vs. 67.3 ± 10.9, p = 0.0020), failed fewer drugs (0.39 vs. 0.60, p = 0.007), had smaller LA size (4.12 ± 0.58 vs. 4.48 ± 0.59 cm, p < 0.0001), lower BMI (28.8 ± 5.0 vs. 30.3 ± 6.0, p = 0.016), and less CAD (3.7% vs. 11.5%, p = 0.007), cardiomyopathies (2.2% vs. 22.9%, p = 0.0001), hypertension (46.7% vs. 67.4%, p < 0.0001), diabetes (8.1% vs. 17.4%, p = 0.011) and sleep apnea (20.0% vs. 30.3%, p = 0.031). For NEWPaAF, early ablation AF-free outcome was no better than later ablation (p = 0.314). For NEWPeAF, AF-free outcomes were better for early ablation than later ablation (p < 0.0001). Delaying ablation allowed more strokes/TIAs in both AF types (paroxysmal p = 0.014, persistent p < 0.0001). CONCLUSIONS: Patients presenting for early ablation after newly diagnosed persistent AF have more pre-existing comorbidities and worse initial ablation outcomes than patients with NEWPaAF. For NEWPaAF, there was no advantage to early ablation, as long as the AF remained paroxysmal. For NEWPeAF, early ablation gave better outcomes than later ablation and they should undergo early ablation. For both AF types, waiting was associated with more neurologic events, suggesting all patients should consider earlier ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Recurrencia , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Masculino , Ablación por Catéter/efectos adversos , Femenino , Persona de Mediana Edad , Factores de Tiempo , Anciano , Factores de Riesgo , Resultado del Tratamiento , Frecuencia Cardíaca , Tiempo de Tratamiento , Potenciales de Acción , Estudios Retrospectivos
17.
J Biol Chem ; 300(3): 105735, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38336298

RESUMEN

One of the independent risk factors for atrial fibrillation is diabetes mellitus (DM); however, the underlying mechanisms causing atrial fibrillation in DM are unknown. The underlying mechanism of Atrogin-1-mediated SK2 degradation and associated signaling pathways are unclear. The aim of this study was to elucidate the relationship among reactive oxygen species (ROS), the NF-κB signaling pathway, and Atrogin-1 protein expression in the atrial myocardia of DM mice. We found that SK2 expression was downregulated comitant with increased ROS generation and enhanced NF-κB signaling activation in the atrial cardiomyocytes of DM mice. These observations were mimicked by exogenously applicating H2O2 and by high glucose culture conditions in HL-1 cells. Inhibition of ROS production by diphenyleneiodonium chloride or silencing of NF-κB by siRNA decreased the protein expression of NF-κB and Atrogin-1 and increased that of SK2 in HL-1 cells with high glucose culture. Moreover, chromatin immunoprecipitation assay demonstrated that NF-κB/p65 directly binds to the promoter of the FBXO32 gene (encoding Atrogin-1), regulating the FBXO32 transcription. Finally, we evaluated the therapeutic effects of curcumin, known as a NF-κB inhibitor, on Atrogin-1 and SK2 expression in DM mice and confirmed that oral administration of curcumin for 4 weeks significantly suppressed Atrogin-1 expression and protected SK2 expression against hyperglycemia. In summary, the results from this study indicated that the ROS/NF-κB signaling pathway participates in Atrogin-1-mediated SK2 regulation in the atria of streptozotocin-induced DM mice.


Asunto(s)
Diabetes Mellitus Experimental , Atrios Cardíacos , Proteínas Musculares , FN-kappa B , Especies Reactivas de Oxígeno , Proteínas Ligasas SKP Cullina F-box , Transducción de Señal , Canales de Potasio de Pequeña Conductancia Activados por el Calcio , Animales , Ratones , Fibrilación Atrial/etiología , Fibrilación Atrial/genética , Fibrilación Atrial/metabolismo , Fibrilación Atrial/fisiopatología , Línea Celular , Inmunoprecipitación de Cromatina , Curcumina/farmacología , Curcumina/uso terapéutico , Diabetes Mellitus Experimental/inducido químicamente , Diabetes Mellitus Experimental/complicaciones , Diabetes Mellitus Experimental/tratamiento farmacológico , Regulación de la Expresión Génica/efectos de los fármacos , Glucosa/farmacología , Atrios Cardíacos/metabolismo , Atrios Cardíacos/fisiopatología , Peróxido de Hidrógeno/farmacología , Hiperglucemia/genética , Hiperglucemia/metabolismo , Proteínas Musculares/genética , Proteínas Musculares/metabolismo , Miocardio , Miocitos Cardíacos , FN-kappa B/antagonistas & inhibidores , FN-kappa B/metabolismo , Proteolisis , Especies Reactivas de Oxígeno/metabolismo , ARN Interferente Pequeño , Proteínas Ligasas SKP Cullina F-box/genética , Proteínas Ligasas SKP Cullina F-box/metabolismo , Canales de Potasio de Pequeña Conductancia Activados por el Calcio/genética , Canales de Potasio de Pequeña Conductancia Activados por el Calcio/metabolismo
19.
JAMA Cardiol ; 9(1): 72-77, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38019505

RESUMEN

Importance: In treating atrial fibrillation, pulsed field ablation (PFA) is a novel energy modality with comparable efficacy to conventional thermal ablation, such as radiofrequency ablation (RFA), but with the benefit of some preferentiality to myocardial tissue ablation. Studies have demonstrated important safety advantages, including the absence of esophageal injury or pulmonary vein stenosis and only rare phrenic nerve injury. However, there is emerging evidence of coronary artery vasospasm provoked by PFA. Objective: To compare the incidence and severity of left circumflex arterial vasospasm between PFA and RFA during adjacent ablation along the mitral isthmus. Design, Setting, and Participants: This prospective cohort study enrolled consecutive adult patients receiving first-ever PFA or RFA of the mitral isthmus during catheter ablation of atrial fibrillation in 2022 with acute follow-up at a single referral European center. Exposure: A posterolateral mitral isthmus line was created using either a multielectrode pentaspline PFA catheter (endocardial ablation) or a saline-irrigated RFA catheter. Simultaneous diagnostic coronary angiography was performed before, during, and after catheter ablation. Nitroglycerin was planned for spasm persisting beyond 20 minutes or for significant electrocardiographic changes. Main Outcomes and Measures: The frequency and severity of left circumflex arterial vasospasm was assessed and monitored, as were time to remission and any need for nitroglycerin administration. Results: Of 26 included patients, 19 (73%) were male, and the mean (SD) age was 65.5 (9.3) years. Patients underwent either PFA (n = 17) or RFA (n = 9) along the mitral isthmus. Coronary spasm was observed in 7 of 17 patients (41.2%) undergoing PFA: in 7 of 9 (77.8%) when the mitral isthmus ablation line was situated superiorly and in 0 of 8 when situated inferiorly. Conversely, coronary spasm did not occur in any of the 9 patients undergoing RFA. Of 5 patients in whom crossover PFA was performed after RFA failed to achieve conduction block, coronary spasm occurred in 3 (60%). Most instances of spasm (9 of 10 [90%]) were subclinical, with 2 (20%) requiring nitroglycerin administration. The median (range) time to resolution of spasm was 5 (5-25) minutes. Conclusion and Relevance: When creating a mitral isthmus ablation line during catheter ablation of atrial fibrillation, adjacent left circumflex arterial vasospasm frequently occurred with PFA and not RFA but was typically subclinical.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Vasoespasmo Coronario , Adulto , Humanos , Masculino , Anciano , Femenino , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Vasoespasmo Coronario/etiología , Nitroglicerina , Estudios Prospectivos , Ablación por Catéter/efectos adversos , Atrios Cardíacos/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...